Por favor, use este identificador para citar o enlazar este ítem: http://dspace.udla.edu.ec/handle/33000/12887
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorGordón Vinueza, Yadira Vanessa-
dc.creatorCollaguazo Troya, Estefania-
dc.creatorGuevara Minango, Pamela Alexandra-
dc.date.accessioned2020-11-14T03:13:39Z-
dc.date.available2020-11-14T03:13:39Z-
dc.date.issued2020-
dc.identifier.citationCollaguazo, E.; Guevara, M. (2020). Medición del gasto energético mediante parámetros fisiológicos en trabajadores de la construcción de la compañía SEMAICA en la edificación de la parte II de la Universidad de las Américas (Tesis de pregrado o de maestría). Universidad de las Américas, Quito.es_ES
dc.identifier.otherUDLA-EC-TLFI-2020-20-
dc.identifier.urihttp://dspace.udla.edu.ec/handle/33000/12887-
dc.descriptionOBJECTIVE: Measure energy expenditure using physiological parameters in construction workers at the SEMAICA construction company in the city of Quito. MATERIAL AND METHOD: Descriptive cross-sectional study, a sample of 20 workers from the construction company SEMAICA was obtained, taking into account the activities carried out by each worker in 8 working hours, heart rate was measured using a chest heart rate monitor and a Polar Beat smartphone application, located 2 workers per day, where the basal heart rate, the average and maximum heart rate could be recorded, this will vary according to the activity carried out, in this way energy consumption can be measured through the heart rate using the criteria by Chamoux RESULTS: For the results of the comparison between work groups, it was obtained using the Chi square (Chi 2), which yielded significant data corresponding to: the relative absolute cost (p = 0.012186) between the group of microcircuits and braces, heart rate mean (p = 0.036715) between the group of microcircuits and carpenters and finally in the absolute cardiac cost (p = 0.047203) when comparing between the group of iron workers and carpenters. CONCLUSIONS: In this study it was evidenced that 80 percent of the workload was very light, the remaining 20 percent carried out activities with a light workload; however, no worker exceeded his physical load, that is, each task is adapted to the worker. KEY WORDS: Energy expenditure, heart rate, oxygen consumption, workers, Chamoux criteria.en
dc.description.abstractOBJETIVO: Medir el gasto energético en trabajadores de la construcción mediante parámetros fisiológicos, en la constructora SEMAICA en la ciudad de Quito…es_ES
dc.format.extent86 p.es_ES
dc.language.isospaes_ES
dc.publisherQuito: Universidad de las Américas, 2020es_ES
dc.rightsopenAccesses_ES
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectFRECUENCIA CARDIACAes_ES
dc.subjectOXÍGENOes_ES
dc.subjectFISIOTERAPIAes_ES
dc.subjectACTIVIDADES FÍSICASes_ES
dc.titleMedición del gasto energético mediante parámetros fisiológicos en trabajadores de la construcción de la compañía SEMAICA en la edificación de la parte II de la Universidad de las Américases_ES
dc.typebachelorThesises_ES
Aparece en las colecciones: Licenciatura en Fisioterapia

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
UDLA-EC-TLFI-2020-20.pdf2,75 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons