Por favor, use este identificador para citar o enlazar este ítem: http://dspace.udla.edu.ec/handle/33000/11898
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorFlores Araque, María Elena-
dc.creatorQuintero Román, Paul Alexander-
dc.date.accessioned2020-02-11T22:32:07Z-
dc.date.available2020-02-11T22:32:07Z-
dc.date.issued2019-
dc.identifier.citationQuintero Román, P. A. (2019). Evaluación de la resistencia adhesiva del cerómero cementado con resinas precalentadas y cemento dual (Tesis de maestría). Universidad de las Américas, Quito.es_ES
dc.identifier.otherUDLA-EC-TEMRO-2019-18-
dc.identifier.urihttp://dspace.udla.edu.ec/handle/33000/11898-
dc.descriptionObjective: Evaluate the adhesive strength between the ceromer, cemented with preheated composite and dual cement. Introduction: Nowadays, there are different techniques to perform indirect and direct restorations. However, due to the benefits of indirect restorations, the main advantages that these presents are, better marginal sealing, easy elaboration of de contact point and occlusal morphology, less stress due to polymerizacion and greater durability of the restorations. There are several materials to cement these restorations, including dual cements and preheated composites. There are several studies that support the use of these materials, but there is no consensus regarding which material provides better adhesive strength. Material and methods: Experimental study, in-vitro. A sample of 20 third molars was used. The sample was divided into two groups (n = 10); in the first group, dual cement was applied, and in the second group, preheated composite was used. A crosscut of 1 ± 0.2 mm was performed per sample to obtain rods, and perform a microtensile test. Results: To generate adhesive fractures in the cemented ceromer samples with preheated composites, a pressure of 0.055 Mpa (IQR=0,015) was needed. While in the cemented ceromer samples with dual cement, a pressure of 0.038 Mpa (IQR=0,015) was required. Results were statistically significant (p major 0.0001), supporting the use of preheated composite. Conclusions: After comparing the pressure needed to cause adhesive fractures in cemented ceromer samples with preheated composite vs samples with dual cement, it was found that greater pressure (0.017 Mpa) is needed to break the adhesive bond in the preheated composite group.en
dc.description.abstractObjetivo: Evaluar la resistencia adhesiva entre el cerómero, cementado con resinas precalentadas y cemento dual. Introducción: En la actualidad existen diferentes técnicas para realizar restauraciones de forma indirecta y directa, por sus beneficios hoy en día muchos profesionales prefieren elaborar las restauraciones en forma indirecta, las principales ventajas que estas presentan son, mejor sellado marginal, fácil elaboración de los puntos de contactos y de la morfología oclusal, menor estrés por polimerización y mayor durabilidad de las restauraciones...es_ES
dc.format.extent70 p.es_ES
dc.language.isospaes_ES
dc.publisherQuito: Universidad de las Américas, 2019es_ES
dc.rightsopenAccesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
dc.subjectODONTOLOGÍA RESTAURADORAes_ES
dc.subjectRESINASes_ES
dc.subjectESTÉTICA DENTALes_ES
dc.titleEvaluación de la resistencia adhesiva del cerómero cementado con resinas precalentadas y cemento duales_ES
dc.typemasterThesises_ES
Aparece en las colecciones: Especialista Médico en Rehabilitación Oral

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
UDLA-EC-TEMRO-2019-18.pdf2,18 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons