Por favor, use este identificador para citar o enlazar este ítem: http://dspace.udla.edu.ec/handle/33000/7508
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorDomínguez Rodríguez, Francisco Javier-
dc.creatorAcosta Yépez, Michelle Paola-
dc.date.accessioned2017-09-25T16:29:27Z-
dc.date.available2017-09-25T16:29:27Z-
dc.date.issued2017-
dc.identifier.citationAcosta Yépez, M. P. (2017). Propuesta de optimización del tratamiento de aguas residuales de la empresa Danec, S. A. (Tesis de pregrado). Universidad de las Américas, Quito.es_ES
dc.identifier.otherUDLA-EC-TIAM-2017-02-
dc.identifier.urihttp://dspace.udla.edu.ec/handle/33000/7508-
dc.descriptionThe effluents from the food industries have high contents of oils and fat, so it is necessary to treat these effluents in order to comply with the National Standards. The effluents in this scope were characterized by high amounts of oils and fat (10447,80 mg / l), BOD5 (1600 mg / l), COD (28900 mg / l), turbidity (1091,5) and pH (8,7). The objective of this thesis is to optimize the wastewater treatment of the DANEC company. Through the implementation of a primary treatment. Two primary treatments were executed: dissolved air flotation and electroflotation at 5, 15 and 30 minutes, respectively, with an adjusted pH of 5 and the use of the electrolytic medium with H2SO4. Subsequently, the coagulation-flocculation technology was applied, using 40 ml of 0,075 percent aluminum polychloride and 23 ml of the 0,1 percent anionic polyelectrolyte adjuvant. The experimental designs that were used, allowed us to conclude that the best treatment was the dissolved air flotation method with a residence time of 5 minutes, due to the turbidity removal of 99,5 percent; COD of 99,5 percent and composition of oils and fat of 99,8 percent, reaching values of 5,2 NTU, 39,6 mg/l, 95,3 mg/l and 14 mg/l, respectively. This treatment complies with the maximum permissible limits of the Regulatory Legal Framework of the Ministerial Agreement.en
dc.description.abstractLos efluentes provenientes de las industrias alimenticias, poseen elevados contenidos de aceites y grasas, por lo que se hace necesario realizar un tratamiento para ser evacuados en los cuerpos de agua dulce…es_ES
dc.format.extent69 p.es_ES
dc.language.isospaes_ES
dc.publisherQuito: Universidad de las Américas, 2017es_ES
dc.rightsopenAccesses_ES
dc.subjectTRATAMIENTO DE AGUASes_ES
dc.subjectAGUAS RESIDUALESes_ES
dc.subjectINGENIERÍA AMBIENTALes_ES
dc.titlePropuesta de optimización del sistema de tratamiento de aguas residuales de la empresa DANEC S. A.es_ES
dc.typebachelorThesises_ES
Aparece en las colecciones: Ingeniería Ambiental en Prevención y Remediación

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
UDLA-EC-TIAM-2017-02.pdf2,13 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.