Por favor, use este identificador para citar o enlazar este ítem: http://dspace.udla.edu.ec/handle/33000/2505
Tipo de material : bachelorThesis
Título : Diseño del sistema de filtración de aguas para consumo en la comunidad Las Balsas (Parroquia San Gregorio - Cantón Muisne)
Autor : Arboleda Tulcanaza, René Sebastián
Tutor : Almeida Naranjo, Cristina Elizabeth
Palabras clave : HIDROLOGÍA;CONTAMINACIÓN;CONTAMINACIÓN INDUSTRIAL;RECURSOS HÍDRICOS
Fecha de publicación : 2015
Editorial : Quito: Universidad de las Américas, 2015
Citación : Arboleda Tulcanaza, R. S. (2015). Diseño del sistema de filtración de aguas para consumo en la comunidad Las Balsas (Parroquia San Gregorio - Cantón Muisne) (Tesis de pregrado). Universidad de las Américas, Quito.
Resumen : Ecuador es un país en el cual el uso de fuentes alternativas de agua no convencionales se produce de manera frecuente, especialmente en zonas o poblados alejados de fuentes de agua segura. El presente trabajo de titulación se encontró encaminado a desarrollar y medir la efectividad de remoción de contaminantes de un bio filtro de agua para la comunidad Las Balsas de la Parroquia San Gregorio del Cantón Muisne, con la finalidad de obtener agua de calidad para los pobladores....
Descripción : Ecuador is a country where the use of alternative sources of non-conventional water occurs frequently, especially in areas or villages far away from sources of safe water. The present study is meant to develop and measure the effectiveness of removing contaminants from a water filter for Las Balsas community, located in the parish of San Gregorio, Muisne; under controlled conditions in order to obtain data on pollutant removal and then identification of the best alternatives for appropriate treatment to comply with the maximum permissible values established by the national laws. The data collection was performed on two occasions where samples of both raw water was taken untreated, such as water and treated water by the implanted in the community system further the community system with 3 types of similar systems but compared two variants: the first variant was the height of the filter bed and the second was the retention time of the water in the system. The results obtained are placed within the maximum permissible limits of the reference standard INEN 1108, making the systems used are adequate for proper treatment, however there was a case in which it was not possible to comply, in the case of the microbiological parameter fecal coliform so it is necessary to supplement the treatment with chlorination to completely eliminate this parameter..
URI : http://dspace.udla.edu.ec/handle/33000/2505
Aparece en las colecciones: Ingeniería Ambiental en Prevención y Remediación

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
UDLA-EC-TIAM-2015-06(S).pdfTESIS A TEXTO COMPLETO15,07 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons